BOQ format

How to quote plumbing and sanitary work

How plumbing and sanitary work is split on an interior BOQ, and why who supplies the CP fittings changes who is responsible when one leaks.

The unit

Point (nos) for the rough-in, each fixture priced separately

Concealed work is counted as points — inlet, outlet, drainage. The visible sanitaryware and CP fittings are separate lines because they are usually chosen by the client after the walls are closed.

What the BOQ breaks into

LineUnitWhy it is its own line
Inlet pointsnosHot and cold counted separately where both run.
Drainage pointsnos
Concealed pipingrftWhere priced by length rather than by point.
SanitarywarenosWC, basin, tub. Supply or install-only — say which.
CP fittingsnosTaps, showers, health faucets. Most often client-supplied.
Water heater provisionnos
Chasing and making goodrftCutting the wall and closing it is civil work inside a plumbing line.

The specs that decide the rate

Pipe material and class
CPVC, PPR or composite, and the pressure class. Concealed for the life of the building.
Who supplies what
Client-supplied fittings are normal and fine, but the BOQ must say so on the line — it decides who replaces a failed cartridge in year two.
Concealed valve brand
The part nobody sees and everybody regrets. A diverter body is not a place to save.

Client-supplied fittings with no line saying so

Most Indian interior jobs have the client buying CP fittings themselves. If the BOQ does not record that, the studio is assumed to have supplied them — and is asked to replace one at its own cost when it drips eighteen months later. A supply/install column on every fixture line settles it before it happens.

Houscade writes this breakdown for you, room by room, and the client approves it on their phone. See a real quotation.